Job PO # | 18-34 | SCS Job # | J-18-18563 |
Sales Engineeer | Z - Norm Comfort | 406-451-7230 | Project Admin | Z - Liz Pullman | 406-551-7221 |
Updated | 12/06/2022 3:46 pm |
PO | Shipping | Delivery | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SCS PO# | MANUFACTURER | TAG | LINE | DESCRIPTION | ORD | SHIP | DELV | B/O | STATUS | ORIGINAL ESTIMATED SHIP DATE | REVISED ESTIMATED SHIP DATE | ACTUAL SHIP DATE | TRACKING | NOTES | ESTIMATED DELIVERY DATE | ACTUAL DELIVERY DATE | SIGNED | NOTES |
18-18563-01 | Johnson Controls | Line 1 | 24" Seismic Rated and Stamped Roof Curbs.
(6) CRBW-SUN03FA-2401-AS
(2) CRBW-PRD01FA-2411-AS
| 8 | 8 | 8 | 0 | DELIVERED | 11/20/2018 | 11/19/2018 | Tri Tech Logistics 6578889217 | 11/24/2018 | 11/24/2018 | NA | ||||
18-18563-02 | Thybar Corporation | Line 1 | 24" Seismic Rated and Stamped Roof Curb. Model: TC-3 for RenewAire HE4XRT. | 1 | 1 | 1 | 0 | DELIVERED | 12/19/2018 | 12/11/2018 | SAIA NA | 01/01/2019 | 01/03/2019 | NA | ||||
18-18563-03 | Renew Aire | Line 1 | **Basis of Design**
RenewAire Model: HE4XRT Heat Recovery Ventilator. RTV Configuration.
-Factory mounted VFDs Supply and Exhaust 5 HP
-BACnet MS/TP Factory Activation
-460V/3PH
-MERV 8 Filters
-Motorized Damper both Air Streams
-Double Wall Cabinet
-Fused Disconnect
Tag: ERV-1 | 1 | 1 | 1 | 0 | DELIVERED | 11/27/2018 | 11/15/2018 | CH robinson NA | 11/28/2018 | 11/28/2018 | NA | ||||
18-18563-05 | Nailor Industries | Line 1 | Nailor Rush Duct Accessories. | 1 | 1 | 1 | 0 | DELIVERED | 01/09/2019 | 01/02/2019 | Old Dominion 10422738327 | 01/08/2019 | 01/08/2019 | |||||
Line 2 | Dynamic Fire Damper
-Horizontal Mounting
-Fusible Link 165°F
-Retaining Angles | 6 | 6 | 6 | 0 | DELIVERED | ||||||||||||
Line 3 | Duct Access Doors. | 6 | 6 | 6 | 0 | DELIVERED | ||||||||||||
Line 4 | Manual Volume Damper with locking quadrant and 2" standoff. | 70 | 70 | 70 | 0 | DELIVERED | ||||||||||||
18-18563-06 | Flexmaster | Line 1 | Boxes Insulated Flex Duct, 25' per Box. | 15 | 15 | 15 | 0 | DELIVERED | 12/25/2018 | 12/18/2018 | XPO 775-182505 | 01/04/2019 | 01/04/2019 | NA | ||||
Line 2 | High Efficiency take-offs without integral volume damper. | 5 | 5 | 5 | 0 | DELIVERED | ||||||||||||
Line 3 | High Efficiency take-offs with integral volume damper. | 60 | 60 | 60 | 0 | DELIVERED | ||||||||||||
18-18563-07 | West Coast - Omniduct | Line 1 | Lot Low Pressure Galvanized Single Wall Round Spiral Ductwork, and Fittings. Supports, hangers, testing, installation, and square to rounds by others. | 1 | 1 | 1 | 0 | DELIVERED | 12/28/2018 | 12/21/2018 | Motor Freight NA | 01/05/2019 | 01/05/2019 | NA | ||||
18-18563-08 | Crescent Electric | Line 1 | Electric Wall Unit Heater.
-4800 Watts
-Unit Mounted Thermostat
Tags: EWH-1,2,3 | 3 | 3 | 3 | 0 | DELIVERED | 02/01/2019 | 02/05/2019 | FedEx NA | 02/14/2019 | 02/14/2019 | NA | ||||
18-18563-09 | Nailor Industries | Line 1 | 1st Release of GRDs Storage 123 & Gate 03 | 30 | 30 | 30 | 0 | DELIVERED | 03/21/2019 | 03/14/2019 | Old Dominion 10422859941 | 03/28/2019 | 03/28/2019 | NA | ||||
18-18563-10 | Nailor Industries | Line 1 | Final Release of ALL remaining GRDs. | 124 | 124 | 124 | 0 | DELIVERED | 04/19/2019 | 04/15/2019 | 04/15/2019 | Old Dominion 10423317204 | 04/23/2019 | 04/23/2019 | NA | |||
18-18563-11 | Thermal Supply | Line 1 | Split System Indoor/Outdoor Unit.
-30,000 BTUs Cooling
-Low Ambient to -40°F
-Condensate Pump
-Line Sets
Tag: FC-1, CU-1 | 1 | 1 | 1 | 0 | DELIVERED | 03/21/2019 | 03/14/2019 | Mergenthaler NA | 03/21/2019 | 03/21/2019 | NA | ||||
18-18563-12 | Mason Industries | Line 1 | For HVAC Dry Side Scope of work; 1 Lot of Seismic Isolation PER IBC 2012 and Specifications (Seismic Design Category = D, Ip = 1.0)as follows:
• HVAC Dry Side Seismic Isolation including ductwork 6 square feet area and larger, 28” Ø duct and larger, hanging equipment:
• Hanger Locations which include 2 seismic cables per location,
• Attachment and equipment overturn calculations that will provide engineered anchoring details per local seismic requirements: FC-1
• Separate Calculations required for equipment attachments –
• As Required Engineered and PE Stamped shop drawings:
• Quality control documentation and site verification.
****Nuts, bolts, washers, guides, rods, strut, steel angle, cutters, crimpers, embeds and anchor bolts, AND ROD STIFFENERS, AND VIBRATION ISOLATION (other than what has specifically delineated above), AS WELL AS EXISTING PIPE/DUCT/EQUIPMENT by others.
| 1 | 1 | 1 | 0 | DELIVERED | 05/07/2019 | 04/30/2019 | OTHER NA | |||||||
18-18563-13 | Johnson Controls | Line 1 | Factory Authorized Startup RTU-1 through 8 | 1 | 0 | 0 | 0 | ORDERED | ||||||||||
18-18563-14 | Johnson Controls | Line 1 | RTU Flue Extension Kit, Part # 1FE0410 | 1 | 1 | 1 | 0 | DELIVERED | 08/23/2019 | 08/16/2019 | OTHER NA | 08/16/2019 | 08/16/2019 | |||||
18-18563-15 | Nailor Industries | Line 1 | Change Order Fire Dampers.
Nailor Model: D1201, 36" x 18" | 2 | 2 | 2 | 0 | DELIVERED | 08/27/2019 | 08/20/2019 | XPO 972397215 | 08/29/2019 | 08/29/2019 | NA | ||||
18-18563-16 | Metropolitan Air Technology | Line 1 | Metropolitan Air Technology Remote Operators:
(62) EB-UDD Worm Gear Drive w/9V Motor
(62) EB-25FT-FS 25ft wire bundle
(1) EB-RC-KIT Hand-Held Remote Control
| 62 | 62 | 62 | 0 | DELIVERED | 12/10/2019 | 12/02/2019 | 12/09/2019 | 12/09/2019 | ||||||
18-18563-17 | Crescent Electric | Line 1 | Model: SSARWH4808, 208V/1PH, 1800-4800 Watts | 1 | 1 | 1 | 0 | DELIVERED | 06/09/2020 | 06/01/2020 | FED-EX NA | 06/05/2020 | 06/05/2020 | NA | ||||
18-18563-18 | Johnson Controls | Line 1 | FUSES | 2 | 2 | 2 | 0 | DELIVERED | ||||||||||
Line 2 | TRANSFORMER. | 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
Line 3 | CONTROL BOARD | 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
18-18563-19 | S&W Heating And AC | Line 1 | Troubleshooting onsite trip | 1 | 0 | 0 | 0 | ORDERED | ||||||||||
18-18563-20 | Crescent Electric | Line 1 | Replacement Wal Heaters | 1 | 1 | 1 | 0 | DELIVERED | 02/08/2021 | 02/01/2021 | FED-EX 783135583850 | 02/01/2021 | 02/01/2021 | comfort | ||||
18-18563-01 | Johnson Controls | Line 1 | JCI Packaged Roof Top Units.
-High Efficiency
-Gas Fired Heat 2 Stages (400MBH Input RTUs-1,2,3,4,5, 8) (80MBH Input RTU-6,7
-4 Stages of Cooling RTUs-1,2,3,4,5, 8
-1 Stage of Cooling RTU-6,7
-Economizer with Power Exhaust
-BACNet MSTP
-Powered Convenience Outlet
-Hail Guard Kit
Tags: RTU-1 through RTU-8 | 8 | 0 | 0 | 0 |