Job PO # | 19-1019 | SCS Job # | J-18-1650 |
Sales Engineeer | Gary Wambeke | 406-451-7232 | Project Admin | Z - Liz Pullman | 406-551-7221 |
Updated | 12/06/2022 3:53 pm |
PO | Shipping | Delivery | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SCS PO# | MANUFACTURER | TAG | LINE | DESCRIPTION | ORD | SHIP | DELV | B/O | STATUS | ORIGINAL ESTIMATED SHIP DATE | REVISED ESTIMATED SHIP DATE | ACTUAL SHIP DATE | TRACKING | NOTES | ESTIMATED DELIVERY DATE | ACTUAL DELIVERY DATE | SIGNED | NOTES |
18-1650-01 | Acme Engineering | Line 1 | ACME Model PRN110
-Backdraft Damper
-Roof Curb
-Speed Controller
Tag: X-Ray Room | 1 | 1 | 1 | 0 | DELIVERED | 07/24/2019 | 07/23/2019 | 07/23/2019 | 07/30/2019 | 07/30/2019 | |||||
18-1650-02 | Thybar Corporation | Line 1 | AHU7 & AHU8 Standard Seismic Curbs - .25/12 Pitch Short Side - 24" Tall Curbs | 2 | 2 | 2 | 0 | DELIVERED | 09/06/2019 | 08/28/2019 | B2B 194407 | 09/04/2019 | 09/04/2019 | NA | ||||
18-1650-03 | IAC Acoustics | Line 1 | Phase I duct Silencers | 11 | 11 | 11 | 0 | DELIVERED | 09/13/2019 | 09/12/2019 | Best Na | 09/15/2019 | 09/15/2019 | NA | ||||
Line 2 | 1 | 1 | 1 | 0 | DELIVERED | |||||||||||||
18-1650-04 | Vemco, Inc | Line 1 | CRU-1 & CRU-2 & CRU-6 Computer room units. COOLING to -30
ALL LINESETS BY OTHERS | 3 | 3 | 3 | 0 | DELIVERED | 10/07/2019 | 10/02/2019 | OTHER NA | 10/04/2019 | 10/07/2019 | |||||
Line 2 | CRU-5 - Computer Room Unit - ALL LINESETS BY OTHERS | 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
18-1650-05 | Thermal Supply | Line 1 | CRU-3 & 4 Computer room units. COOLING to -30, Wired Wall Controller with connection Cord, 50' Insulated Lineset, ASPEN Mini White Condensate Pump, Fused Disconnect, BACNet Communications
ALL STARTUP BY OTHERS | 2 | 2 | 2 | 0 | DELIVERED | 09/05/2019 | 08/09/2019 | TSI Delivery NA | 09/05/2019 | 09/05/2019 | NA | ||||
18-1650-06 | BLC Industries | Line 1 | HF2 & HF3 HEPA FILTER Housings
SURE-LINE 26HL01X21 (1,000 CFM @ 500 FPM)
Units Description
16 Gauge – Aluminized Steel Construction
Compact 26” Overall Unit Depth
Standard Horizontal Airflow
304 Stainless Steel Locking Mechanism
Standard Unit Pressure – 4” W.G
Gasket Seal Construction
2” Prefilter if required
Unique BLC Door J-Seal – Double Turned Flange
Cross-Broke Cap Style Doors w/Cap Seal (No Flat Seal)
Individual Door – Neoprene Gasket
(2) Bolt-On Doors provided Left OR Right
Lift-off Doors with Positive Pressure Knobs
Replaceable Unit Hardware and Tracks
Units designed to ASHRAE, ANSI and SMACNA Guidelines
One Year Factory Warranty for Parts and Workmanship
Housing Option Adds:
(3) Adds for Weatherproofing with Full Unit Weathercap
Initial Set of Filters:
(3) FILTER-LINE FLICP08 Industrial Class Pleat 12 x 24 x 2 (MERV 08)
(3) FILTER-LINE FLH97/121224 (99.97% High Capacity HEPA)
(1) SET SPARE FILTERS
Factory Mounted Dwyer Gage Options:
(3) Factory Mounted Dwyer Magnehelic Gage – 2004
| 2 | 2 | 2 | 0 | DELIVERED | 09/19/2019 | 09/12/2019 | best NA | 09/16/2019 | 09/16/2019 | NA | ||||
Line 2 | HF1 HEPA FILTER Housings
SURE-LINE 26HL01X21 (1,000 CFM @ 500 FPM)
Units Description
16 Gauge – Aluminized Steel Construction
Compact 26” Overall Unit Depth
Standard Horizontal Airflow
304 Stainless Steel Locking Mechanism
Standard Unit Pressure – 4” W.G
Gasket Seal Construction
2” Prefilter if required
Unique BLC Door J-Seal – Double Turned Flange
Cross-Broke Cap Style Doors w/Cap Seal (No Flat Seal)
Individual Door – Neoprene Gasket
(2) Bolt-On Doors provided Left OR Right
Lift-off Doors with Positive Pressure Knobs
Replaceable Unit Hardware and Tracks
Units designed to ASHRAE, ANSI and SMACNA Guidelines
One Year Factory Warranty for Parts and Workmanship
Housing Option Adds:
(3) Adds for Weatherproofing with Full Unit Weathercap
Initial Set of Filters:
(3) FILTER-LINE FLICP08 Industrial Class Pleat 12 x 24 x 2 (MERV 08)
(3) FILTER-LINE FLH97/121224 (99.97% High Capacity HEPA)
(1) SET SPARE FILTERS
Factory Mounted Dwyer Gage Options:
(3) Factory Mounted Dwyer Magnehelic Gage – 2004
| 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
18-1650-07 | Acme Engineering | Line 1 | EF7-1 through EF7-7, EF8-3, 8-4 & 8-10 Roof Mounted Exhaust Fans with Back Draft Damper and Curbs | 10 | 10 | 10 | 0 | ORDERED | 08/20/2019 | 11/15/2019 | 11/15/2019 | ABF 081355414 | 11/23/2019 | 11/23/2019 | ||||
Line 2 | EF7-8, EF-8-7 Roof Mounted Utility Set Exhaust Fan with Back Draft Damper
CURB BY GC PER DETAIL 11 M8.3 | 2 | 2 | 2 | 0 | DELIVERED | ||||||||||||
Line 3 | EF2-2, EF2-5, EF8-6, EF8-8, EF8-9, EF8-11, EF8-12 Roof Mounted Exhaust Fans with Back Draft Damper and Curbs | 7 | 7 | 7 | 0 | DELIVERED | ||||||||||||
Line 4 | EF2-3, 2-4 & 8-1 & 8-13 Roof Mounted Exhaust Fans with Back Draft Damper and Curbs | 4 | 4 | 4 | 0 | DELIVERED | ||||||||||||
Line 5 | EF8-5 Roof Mounted Utility Set Exhaust Fan with Back Draft Damper
CURB BY GC PER DETAIL 11 M8.3 | 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
18-1650-08 | Pure Humidifier | Line 1 | H-AHU-7 & 8 Gas fired Steam Generators with Fast Pac Tube Assembly | 2 | 2 | 2 | 0 | DELIVERED | 09/16/2019 | 09/10/2019 | ABF 200-840-915 | 09/19/2019 | 09/17/2019 | NA | ||||
18-1650-09 | Lewis & Lambert | Line 1 | Oval Ductwork/Double Wall Round:
Single Wall Oval Medium Pressure Supply Spiral & Longitudinal Seam Ductwork:
(Duct provided is associated with AHU-7, 8 & S2 Upstream of all Terminal Units beyond 25’-0” the AHU’s.)
• Pressure Classification Is: Positive 4" W.G.
• Construction Of Pipe/Duct and Fittings To Be: G-90 Galvanized Steel
• Pipe/Duct Furnished As: Spiral Pipe & Long Seam Pipe 5’-0” max joints.
• Fittings And/or Assemblies Furnished As: Tack Welded and Sealed
• Transverse Duct Connections Are: Coupling Slip-Fit
• Spiral & Longitudinal Seam pipe supplied as:
o Single Wall Round and Oval With: Oval to Round Transitions, Oval to Oval Transitions, Barrel Fittings & Loose Elbows.
Double Wall Oval Medium & Return Air Spiral & Longitudinal Seam Ductwork:
(Duct provided is associated with AHU-7 & AHU-8, Duct to be Double Wall 25’-0” from the AHU’s.)
• Pressure Classification Is: Positive 4" W.G. for Medium Pressure Supply & Negative 2" W.G. for Return air.
• Construction Of Pipe/Duct And Fittings To Be: G-90 Galvanized Steel
• Pipe/Duct Furnished As: Spiral Pipe & Long Seam Pipe 5’0-“ max joints.
• Fittings And/or Assemblies Furnished As: Tack Welded and Sealed
• Transverse Duct Connections Are: Coupling Slip-Fit
• Rectangular Taps Are: Insulated 8" Long And 1" Flanges Turned Inside
• Rectangular Taps Are Shipped As: Factory Manifolded To The Main Duct
• Spiral & Longitudinal Seam pipe supplies as:
o Double Wall Round With: Oval to Round Transitions, Oval to Oval Transitions, Insulation Ends, Barrel Fittings & Loose Elbows.
• Double Wall Ductwork Will Have: 1" x 1.5Lb Density Antimicrobial Coated Insulation
• Double Wall Duct Inner Liner To Be: 22 GA, Perforated, G-90 Galvanized Steel.
• Double Wall Fittings Inner Liner To Be: 24 GA, Solid, G-90 Galvanized Steel.
Double Wall Round Medium Pressure Supply & Return Air Spiral Ductwork:
(Duct provided is associated with AHU-7 & 8, Duct to be Double Wall 25’-0” from the AHU’s.)
• Pressure Classification Is: Positive 4" W.G. for Medium Pressure Supply & Negative 2" W.G. for Return Air.
• Construction Of Pipe/Duct And Fittings To Be: G-90 Galvanized Steel
• Pipe/Duct Furnished As: Spiral Pipe
• Fittings And/or Assemblies Furnished As: Tack Welded and Sealed
• Transverse Duct Connections Are: Coupling Slip-Fit
• Rectangular Taps Are: Insulated 6" Long And 1" Flanges Turned Inside
• Rectangular Taps Are Shipped As: Factory Manifolded To The Main Duct
• Frames For Flush Mounted Grilles: Factory Manifolded To The Main Duct
• Spiral Pipe Supplied as:
o Double Wall Round With: Barrel Fittings, Insulation Ends & Loose Elbows.
• Double Wall Ductwork Will Have: 1" x 1.5Lb Density Antimicrobial Coated Insulation
• Double Wall Duct Inner Liner To Be: 22 GA, Perforated, G-90 Galvanized Steel.
• Double Wall Fittings Inner Liner To Be: 24 GA, Solid, G-90 Galvanized Steel.
*L & L defines “exposed” as industry standard shop fabricated sheet metal duct with normal machinery markings such as brake, seam, and roller marks, etcetera but otherwise free of material imperfections such as pitting, stains, discolorations.*
Oval Duct converted to L&L Spiral sizes includes the following (I.D.):
50/20 – 52/20
46/20 – 45/20
40/20 – 42/20
34/16 – 35/16
30/16 – 32/16
20/20 – 20” Round (located in Round bid)
| 1 | 1 | 1 | 0 | DELIVERED | 11/27/2019 | 11/20/2019 | OTHER NA | 11/27/2019 | 11/27/2019 | NA | ||||
18-1650-10 | Flexmaster | Line 1 | High Efficiency Take-offs without Dampers | 59 | 59 | 59 | 0 | DELIVERED | 09/04/2019 | 08/22/2019 | OCG 39260 | 08/27/2019 | 08/29/2019 | NA | ||||
Line 2 | High Efficiency Take-offs without Dampers | 71 | 71 | 71 | 0 | DELIVERED | ||||||||||||
Line 3 | High Efficiency Take-offs without Dampers | 48 | 48 | 48 | 0 | DELIVERED | ||||||||||||
18-1650-11 | Nailor Industries | Line 1 | Progressive Invoicing #1
Invoice for Nailor 726104-H
| 1 | 1 | 1 | 0 | DELIVERED | 09/25/2019 | 09/18/2019 | YRC 792-546412-2 | 09/23/2019 | 09/23/2019 | NA | ||||
Line 2 | Rectangular Duct Access doors | 44 | 44 | 44 | 0 | DELIVERED | ||||||||||||
Line 3 | Dynamic Fire Dampers with Sleeve and Retaining Angles both Sides - 165 Degree Closure Temperature. 4000 FPM Max Velocity | 48 | 48 | 48 | 0 | DELIVERED | ||||||||||||
18-1650-12 | ACME Manufacturing | Line 1 | Roof Curbs for GV-1 and GV-2 | 2 | 2 | 2 | 0 | DELIVERED | 09/19/2019 | 09/20/2019 | YRC 7781071566 | 09/27/2019 | 09/27/2019 | MNa | ||||
18-1650-13 | Nailor Industries | Line 1 | Round Duct Access doors | 121 | 121 | 121 | 0 | DELIVERED | 09/06/2019 | 08/27/2019 | YRC 778-251945-X | 09/04/2019 | 09/04/2019 | NA | ||||
18-1650-14 | Mason Industries | Line 1 | For HVAC Dry Side Scope of work; 1 Lot of Mason Industries Seismic Isolation PER IBC 2012 and Specifications (Seismic Design Category = C, Ip = 1.5)as follows:
1) HVAC Dry Side Seismic Isolation including ductwork 6 square feet area and larger and hanging equipment (including VAV’s):
84 Hanger Locations which include 4 seismic cables per location,
2) Attachment and equipment overturn calculations that will provide engineered anchoring details per local seismic requirements:
4 separate calculations required for equipment attachments
3) As Required Engineered and PE Stamped shop drawings:
4) Vibration Isolation Pads and Spring Hangers for equipment and ductwork:
ZERO Spring Hangers or Pads
5) Quality control documentation and site verification.
****Nuts, bolts, washers, guides, rods, strut, steel angle, embeds and anchor bolts, AND ROD STIFFENERS, AND VIBRATION ISOLATION (other than what has specifically delineated above), AS WELL AS EXISTING PIPE/DUCT/EQUIPMENT by others.
| 1 | 1 | 1 | 0 | DELIVERED | 10/11/2019 | 09/27/2019 | ABF 219717744 | 10/04/2019 | 10/04/2019 | |||||
Line 2 | For HVAC Dry Side Scope of work; 1 Lot of Mason Industries Seismic Isolation PER IBC 2012 and Specifications (Seismic Design Category = C, Ip = 1.5)as follows:
1) HVAC Dry Side Seismic Isolation including ductwork 6 square feet area and larger and hanging equipment (including VAV’s):
25 Hanger Locations which include 4 seismic cables per location,
2) Attachment and equipment overturn calculations that will provide engineered anchoring details per local seismic requirements:
4 separate calculations required for equipment attachments
3) As Required Engineered and PE Stamped shop drawings:
4) Vibration Isolation Pads and Spring Hangers for equipment and ductwork:
ZERO Spring Hangers or Pads
5) Quality control documentation and site verification.
****Nuts, bolts, washers, guides, rods, strut, steel angle, embeds and anchor bolts, AND ROD STIFFENERS, AND VIBRATION ISOLATION (other than what has specifically delineated above), AS WELL AS EXISTING PIPE/DUCT/EQUIPMENT by others.
| 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
Line 3 | For HVAC Dry Side Scope of work; 1 Lot of Mason Industries Seismic Isolation PER IBC 2012 and Specifications (Seismic Design Category = C, Ip = 1.5)as follows:
1) HVAC Dry Side Seismic Isolation including ductwork 6 square feet area and larger and hanging equipment (including VAV’s):
17 Hanger Locations which include 4 seismic cables per location,
2) Attachment and equipment overturn calculations that will provide engineered anchoring details per local seismic requirements:
4 separate calculations required for equipment attachments
3) As Required Engineered and PE Stamped shop drawings:
4) Vibration Isolation Pads and Spring Hangers for equipment and ductwork:
ZERO Spring Hangers or Pads
5) Quality control documentation and site verification.
****Nuts, bolts, washers, guides, rods, strut, steel angle, embeds and anchor bolts, AND ROD STIFFENERS, AND VIBRATION ISOLATION (other than what has specifically delineated above), AS WELL AS EXISTING PIPE/DUCT/EQUIPMENT by others.
| 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
Line 4 | For HVAC Dry Side Scope of work; 1 Lot of Mason Industries Seismic Isolation PER IBC 2012 and Specifications (Seismic Design Category = C, Ip = 1.5)as follows:
1) HVAC Dry Side Seismic Isolation including ductwork 6 square feet area and larger and hanging equipment (including VAV’s):
4 Hanger Locations which include 4 seismic cables per location,
2) Attachment and equipment overturn calculations that will provide engineered anchoring details per local seismic requirements:
0 separate calculations required for equipment attachments
3) As Required Engineered and PE Stamped shop drawings:
4) Vibration Isolation Pads and Spring Hangers for equipment and ductwork:
ZERO Spring Hangers or Pads
5) Quality control documentation and site verification.
****Nuts, bolts, washers, guides, rods, strut, steel angle, embeds and anchor bolts, AND ROD STIFFENERS, AND VIBRATION ISOLATION (other than what has specifically delineated above), AS WELL AS EXISTING PIPE/DUCT/EQUIPMENT by others.
| 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
18-1650-15 | Keller Supply | Line 1 | EF-8-2 Ceiling Exhaust Fan | 1 | 1 | 1 | 0 | DELIVERED | 08/28/2019 | 08/21/2019 | UPS NA | 08/21/2019 | 08/21/2019 | NA | ||||
18-1650-16 | Mason Industries | Line 1 | Mason 30-X-12 Hanging Spring Isolators for EF 8-2 | 4 | 4 | 4 | 0 | DELIVERED | 08/30/2019 | 08/23/2019 | 08/30/2019 | 08/30/2019 | NA | |||||
18-1650-17 | Nailor Industries | Line 1 | Class I 250 Degree Rated Grille Mounted Fire/Smoke Damper with Sleeve and 120V Actuator and position indicator end switch | 4 | 4 | 4 | 0 | DELIVERED | 09/20/2019 | 09/13/2019 | XPO 435-161904 | 09/20/2019 | 09/20/2019 | NA | ||||
18-1650-18 | Lewis & Lambert | Line 1 | 1" DW Rectangular Duct per NorPac Cut sheets | 1 | 1 | 1 | 0 | DELIVERED | 10/24/2019 | 10/17/2019 | Best way NA | 10/24/2019 | 10/24/2019 | NA | ||||
18-1650-19 | Nailor Industries | Line 1 | Class I 250 Degree Rated Combination Fire/Smoke Damper with Sleeve and 120V Actuator and position indicator end switch. 1 set Retaining angles | 3 | 3 | 3 | 0 | DELIVERED | 11/29/2019 | 11/22/2019 | XPO 435-077215 | 11/29/2019 | 11/29/2019 | |||||
18-1650-20 | Nailor Industries | Line 1 | Rush for Area A North GRDs. | 1 | 1 | 1 | 0 | DELIVERED | 12/12/2019 | 01/02/2020 | 01/02/2020 | 01/09/2020 | 01/09/2020 | NA | ||||
Line 2 | Grilles, Registers & Diffusers | 97 | 97 | 97 | 0 | DELIVERED | ||||||||||||
18-1650-21 | YRC FREIGHT | Line 1 | YRC Freight shipment to NorPac - Humidifier | 1 | 0 | 0 | 0 | DELIVERED | 12/19/2019 | 12/12/2019 | YRC NA | |||||||
18-1650-22 | Flexmaster | Line 1 | Boxes Low Pressure R6.0 Insulated Flex Duct | 12 | 12 | 12 | 0 | DELIVERED | 01/10/2020 | 01/06/2020 | R&L 295621533 | 01/13/2020 | 01/13/2020 | NA | ||||
18-1650-23 | Nailor Industries | Line 1 | Progressive Invoicing #1
Invoice for Nailor 726042-H, shipped 9/6
726087-H, shipped 9/13
726094-H, shipped 9/16
| 1 | 0 | 0 | 0 | DELIVERED | 11/06/2019 | 10/30/2019 | OTHER NA | 11/07/2019 | 11/07/2019 | NA | ||||
Line 2 | Class I 250 Degree Rated Smoke Damper with Sleeve and 120V Actuator and position indicator end switch | 67 | 67 | 67 | 0 | DELIVERED | ||||||||||||
Line 3 | Manual Volume Dampers with Locking Quadrant and 2" Stand-off | 436 | 436 | 436 | 0 | DELIVERED | ||||||||||||
Line 4 | Opposed Blade Control Damper with 120V Actuator with end switch, mounted externally | 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
Line 5 | Class I 250 Degree Rated Combination Fire/Smoke Damper with Sleeve and 120V Actuator and position indicator end switch. 1 set Retaining angles | 61 | 61 | 61 | 0 | DELIVERED | ||||||||||||
18-1650-24 | Lewis & Lambert | Line 1 | Round Stainless Steel & Aluminum Ductwork:
Single Wall Round Stainless Steel Exhaust Air Longitudinal Seam Ductwork:
(Duct provided is associated with Washer Exhaust Air, Dish Exhaust Air, KH-1, KH-2 & VH-1, 2, 3 & 4.)
• Pressure Classification Is: Negative 2" W.G.
• Construction Of Pipe/Duct and Fittings To Be: Stainless Steel 304 #2B
• Pipe/Duct Furnished As: Long Seam Pipe 4’-11’ Max joints.
• Fittings And/or Assemblies Furnished As: Fully Wire Welded (MIG)
• Transverse Duct Connections Are: 1/2" Weld Flanges
• Longitudinal Seam pipe supplied as:
o Single Wall Round With: Loose Elbows.
Single Wall Round Aluminum Medium/Low Pressure Supply, Return & Exhaust Air Spiral Ductwork:
(Duct provided is associated with Supply, Exhaust & Return Air systems serving the MRI Room.)
• Pressure Classification Is: Positive 4" W.G. for Medium Pressure Supply, Positive 2" W.G. for Low Pressure Supply & Negative 2" W.G. for Exhaust & Return Air.
• Construction Of Pipe/Duct and Fittings To Be: Aluminum 3003 H14
• Pipe/Duct Furnished As: Spiral Pipe
• Fittings And/or Assemblies Furnished As: Tack Welded and Sealed
• Transverse Duct Connections Are: Coupling Slip-Fit
• Spiral Pipe Supplied As:
o Single Wall Round With: Loose Elbows.
*L & L defines “exposed” as industry standard shop fabricated sheet metal duct with normal machinery markings such as brake, seam, and roller marks, etcetera but otherwise free of material imperfections such as pitting, stains, discolorations.*
All 4” Round Duct is converted to 6” Round Duct.
| 1 | 1 | 1 | 0 | DELIVERED | 09/20/2019 | 11/22/2019 | 11/22/2019 | OTHER NA | 11/29/2019 | 11/29/2019 | NA | |||
Line 2 | Oval Ductwork/Double Wall Round:
Single Wall Oval Medium Pressure Supply Spiral & Longitudinal Seam Ductwork:
(Duct provided is associated with AHU-7, 8 & S2 Upstream of all Terminal Units beyond 25’-0” the AHU’s.)
• Pressure Classification Is: Positive 4" W.G.
• Construction Of Pipe/Duct and Fittings To Be: G-90 Galvanized Steel
• Pipe/Duct Furnished As: Spiral Pipe & Long Seam Pipe 5’-0” max joints.
• Fittings And/or Assemblies Furnished As: Tack Welded and Sealed
• Transverse Duct Connections Are: Coupling Slip-Fit
• Spiral & Longitudinal Seam pipe supplied as:
o Single Wall Round and Oval With: Oval to Round Transitions, Oval to Oval Transitions, Barrel Fittings & Loose Elbows.
Double Wall Oval Medium & Return Air Spiral & Longitudinal Seam Ductwork:
(Duct provided is associated with AHU-7 & AHU-8, Duct to be Double Wall 25’-0” from the AHU’s.)
• Pressure Classification Is: Positive 4" W.G. for Medium Pressure Supply & Negative 2" W.G. for Return air.
• Construction Of Pipe/Duct And Fittings To Be: G-90 Galvanized Steel
• Pipe/Duct Furnished As: Spiral Pipe & Long Seam Pipe 5’0-“ max joints.
• Fittings And/or Assemblies Furnished As: Tack Welded and Sealed
• Transverse Duct Connections Are: Coupling Slip-Fit
• Rectangular Taps Are: Insulated 8" Long And 1" Flanges Turned Inside
• Rectangular Taps Are Shipped As: Factory Manifolded To The Main Duct
• Spiral & Longitudinal Seam pipe supplies as:
o Double Wall Round With: Oval to Round Transitions, Oval to Oval Transitions, Insulation Ends, Barrel Fittings & Loose Elbows.
• Double Wall Ductwork Will Have: 1" x 1.5Lb Density Antimicrobial Coated Insulation
• Double Wall Duct Inner Liner To Be: 22 GA, Perforated, G-90 Galvanized Steel.
• Double Wall Fittings Inner Liner To Be: 24 GA, Solid, G-90 Galvanized Steel.
Double Wall Round Medium Pressure Supply & Return Air Spiral Ductwork:
(Duct provided is associated with AHU-7 & 8, Duct to be Double Wall 25’-0” from the AHU’s.)
• Pressure Classification Is: Positive 4" W.G. for Medium Pressure Supply & Negative 2" W.G. for Return Air.
• Construction Of Pipe/Duct And Fittings To Be: G-90 Galvanized Steel
• Pipe/Duct Furnished As: Spiral Pipe
• Fittings And/or Assemblies Furnished As: Tack Welded and Sealed
• Transverse Duct Connections Are: Coupling Slip-Fit
• Rectangular Taps Are: Insulated 6" Long And 1" Flanges Turned Inside
• Rectangular Taps Are Shipped As: Factory Manifolded To The Main Duct
• Frames For Flush Mounted Grilles: Factory Manifolded To The Main Duct
• Spiral Pipe Supplied as:
o Double Wall Round With: Barrel Fittings, Insulation Ends & Loose Elbows.
• Double Wall Ductwork Will Have: 1" x 1.5Lb Density Antimicrobial Coated Insulation
• Double Wall Duct Inner Liner To Be: 22 GA, Perforated, G-90 Galvanized Steel.
• Double Wall Fittings Inner Liner To Be: 24 GA, Solid, G-90 Galvanized Steel.
*L & L defines “exposed” as industry standard shop fabricated sheet metal duct with normal machinery markings such as brake, seam, and roller marks, etcetera but otherwise free of material imperfections such as pitting, stains, discolorations.*
Oval Duct converted to L&L Spiral sizes includes the following (I.D.):
50/20 – 52/20
46/20 – 45/20
40/20 – 42/20
34/16 – 35/16
30/16 – 32/16
20/20 – 20” Round (located in Round bid)
| 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
Line 3 | – Round Stainless Steel & Aluminum Ductwork:
Single Wall Round Stainless Steel Exhaust Air Longitudinal Seam Ductwork:
(Duct provided is associated with Washer Exhaust Air, Dish Exhaust Air, KH-1, KH-2 & VH-1, 2, 3 & 4.)
• Pressure Classification Is: Negative 2" W.G.
• Construction Of Pipe/Duct and Fittings To Be: Stainless Steel 304 #2B
• Pipe/Duct Furnished As: Long Seam Pipe 4’-11’ Max joints.
• Fittings And/or Assemblies Furnished As: Fully Wire Welded (MIG)
• Transverse Duct Connections Are: 1/2" Weld Flanges
• Longitudinal Seam pipe supplied as:
o Single Wall Round With: Loose Elbows.
Single Wall Round Aluminum Medium/Low Pressure Supply, Return & Exhaust Air Spiral Ductwork:
(Duct provided is associated with Supply, Exhaust & Return Air systems serving the MRI Room.)
• Pressure Classification Is: Positive 4" W.G. for Medium Pressure Supply, Positive 2" W.G. for Low Pressure Supply & Negative 2" W.G. for Exhaust & Return Air.
• Construction Of Pipe/Duct and Fittings To Be: Aluminum 3003 H14
• Pipe/Duct Furnished As: Spiral Pipe
• Fittings And/or Assemblies Furnished As: Tack Welded and Sealed
• Transverse Duct Connections Are: Coupling Slip-Fit
• Spiral Pipe Supplied As:
o Single Wall Round With: Loose Elbows.
*L & L defines “exposed” as industry standard shop fabricated sheet metal duct with normal machinery markings such as brake, seam, and roller marks, etcetera but otherwise free of material imperfections such as pitting, stains, discolorations.*
All 4” Round Duct is converted to 6” Round Duct.
| 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
Line 4 | – Round Stainless Steel & Aluminum Ductwork:
Single Wall Round Stainless Steel Exhaust Air Longitudinal Seam Ductwork:
(Duct provided is associated with Washer Exhaust Air, Dish Exhaust Air, KH-1, KH-2 & VH-1, 2, 3 & 4.)
• Pressure Classification Is: Negative 2" W.G.
• Construction Of Pipe/Duct and Fittings To Be: Stainless Steel 304 #2B
• Pipe/Duct Furnished As: Long Seam Pipe 4’-11’ Max joints.
• Fittings And/or Assemblies Furnished As: Fully Wire Welded (MIG)
• Transverse Duct Connections Are: 1/2" Weld Flanges
• Longitudinal Seam pipe supplied as:
o Single Wall Round With: Loose Elbows.
Single Wall Round Aluminum Medium/Low Pressure Supply, Return & Exhaust Air Spiral Ductwork:
(Duct provided is associated with Supply, Exhaust & Return Air systems serving the MRI Room.)
• Pressure Classification Is: Positive 4" W.G. for Medium Pressure Supply, Positive 2" W.G. for Low Pressure Supply & Negative 2" W.G. for Exhaust & Return Air.
• Construction Of Pipe/Duct and Fittings To Be: Aluminum 3003 H14
• Pipe/Duct Furnished As: Spiral Pipe
• Fittings And/or Assemblies Furnished As: Tack Welded and Sealed
• Transverse Duct Connections Are: Coupling Slip-Fit
• Spiral Pipe Supplied As:
o Single Wall Round With: Loose Elbows.
*L & L defines “exposed” as industry standard shop fabricated sheet metal duct with normal machinery markings such as brake, seam, and roller marks, etcetera but otherwise free of material imperfections such as pitting, stains, discolorations.*
All 4” Round Duct is converted to 6” Round Duct.
| 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
18-1650-25 | Nailor Industries | Line 1 | Grilles, Registers and Diffusers | 355 | 355 | 355 | 0 | DELIVERED | 02/21/2020 | 02/14/2020 | 03/02/2020 | FED-EX 167224280134 | 03/09/2020 | 03/09/2020 | ||||
18-1650-26 | Nailor Industries | Line 1 | Grilles, Registers and Diffusers - Security Grilles | 2 | 2 | 2 | 0 | DELIVERED | 03/06/2020 | 02/26/2020 | 03/05/2020 | 03/05/2020 | ||||||
18-1650-27 | Flexmaster | Line 1 | Boxes Low Pressure R6.0 Insulated Flex Duct | 56 | 56 | 56 | 0 | DELIVERED | 01/29/2020 | 01/21/2020 | XPO 229-468886 | 01/28/2020 | 01/28/2020 | NA | ||||
18-1650-28 | Nailor Industries | Line 1 | OR Grilles, Registers and Diffusers | 28 | 28 | 28 | 0 | DELIVERED | 03/12/2020 | 03/05/2020 | ABF 07556548 | 03/13/2020 | 03/13/2020 | |||||
18-1650-29 | Nailor Industries | Line 1 | Class I 250 Degree Rated Combination Fire/Smoke Damper with Sleeve and 120V Actuator and position indicator end switch. 1 set Retaining angles | 2 | 2 | 2 | 0 | DELIVERED | 02/04/2020 | 01/23/2020 | YRC 855-6167123 | 01/30/2020 | 01/30/2020 | NA | ||||
18-1650-30 | Nailor Industries | Line 1 | Replacement SSG-2 GRDs for Area A North | 2 | 2 | 2 | 0 | DELIVERED | 02/28/2020 | 02/17/2020 | FedEx 130844667047 | 02/24/2020 | 02/24/2020 | NA | ||||
18-1650-31 | Nailor Industries | Line 1 | 13 | 13 | 13 | 0 | DELIVERED | 03/06/2020 | 03/13/2020 | FedEx Freight 4932870961 | 03/20/2020 | 03/20/2020 | NA | |||||
18-1650-32 | Nailor Industries | Line 1 | TAG L1 thru L3 Extruded Aluminum Drainable Blade Channel Frame Louvers with Birdscreen and Kynar Equivalent finish. COLOR TO BE SELECTED FROM STANDARD COLOR CHART | 3 | 3 | 3 | 0 | DELIVERED | 03/06/2020 | 02/28/2020 | YRC 855-616634-4 | 03/05/2020 | 03/05/2020 | NA | ||||
Line 2 | TAG L1 30/24 opposed blade damper with 24V Actuator mounted externally with end switch | 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
18-1650-33 | Acme Engineering | Line 1 | GV1 Gravity Intake Ventilator | 1 | 1 | 1 | 0 | DELIVERED | 02/24/2020 | 02/18/2020 | XPO 230-473832 | 02/23/2020 | 02/23/2020 | |||||
Line 2 | GV-2 Gravity Vent with Curb and Back Draft Damper | 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
18-1650-34 | Line 1 | UPS Return shipment of humidifier | 1 | 0 | 0 | 0 | ORDERED | |||||||||||
18-1650-35 | Schebler Company | Line 1 | AL29-4C Double Wall Boiler Flue | 1 | 1 | 1 | 0 | DELIVERED | 02/28/2020 | 02/24/2020 | XPO NA | 03/01/2020 | 03/02/2020 | NA | ||||
18-1650-36 | Commercial Service | Line 1 | Humidifier Startup for H-AHU-7 and H-AHU-8 | 1 | 0 | 0 | 0 | ORDERED | ||||||||||
18-1650-37 | Nailor Industries | Line 1 | GRD Plaster Frames for Lay-In GRDs | 46 | 46 | 46 | 0 | DELIVERED | 04/01/2020 | 03/26/2020 | FED-EX 165153533263 | 04/05/2020 | 04/05/2020 | |||||
18-1650-38 | Pure Humidifier | Line 1 | Pure Humidifier Parts
Qty. 1 - Air Flow Proving Switch
Qty. 2 - HC-201 Schneider Electric On/Off Duct H'stat | 3 | 3 | 3 | 0 | DELIVERED | 03/19/2020 | 03/12/2020 | 03/12/2020 | UPS red NA | 03/13/2020 | 03/13/2020 | ||||
18-1650-39 | Nailor Industries | Line 1 | Replacement aluminum OR Grilles | 2 | 2 | 2 | 0 | DELIVERED | 05/15/2020 | 04/29/2020 | FED-EX 165153542555 | 05/04/2020 | 05/04/2020 | EBollinger | ||||
18-1650-40 | Motion Industries | Line 1 | AHU-S-2 25HP VFD Rated Motor - Replacement for the Supply Fan. Baldor EM2531T ODP 230/460 284T
| 1 | 0 | 0 | 0 | ORDERED | ||||||||||
18-1650-41 | S. Conley Sales | Line 1 | Added $ Changed Items per 7/8/19 Email | 1 | 0 | 0 | 0 | DELIVERED | 05/12/2020 | 05/05/2020 | 05/05/2020 | 05/05/2020 | ||||||
18-1650-42 | S. Conley Sales | Line 1 | Balance of Project | 1 | 0 | 0 | 0 | DELIVERED | 05/12/2020 | 05/05/2020 | 05/05/2020 | 05/05/2020 | ||||||
18-1650-43 | Grainger | Line 1 | Grainger part numbers:
(1) Motor pulley: 10Y285
(1) Bushing: 10Y304
(2) B72 belts
| 1 | 0 | 0 | 0 | ORDERED | 05/29/2020 | 05/22/2020 | 05/22/2020 | 05/22/2020 | ||||||
18-1650-44 | Vemco, Inc | Line 1 | 1 | 1 | 1 | 0 | DELIVERED | 06/10/2020 | 06/03/2020 | FED-EX 173015156154 | 06/08/2020 | 06/08/2020 | MWardell | |||||
18-1650-45 | Keller Supply | Line 1 | Ductmate Access Doors
| 24 | 24 | 24 | 0 | DELIVERED | 08/28/2020 | 08/24/2020 | 08/31/2020 | 08/31/2020 | Amanda | |||||
18-1650-46 | Nailor Industries | Line 1 | 6 | 6 | 6 | 0 | DELIVERED | 10/05/2020 | 09/28/2020 | XPO 855-000484 | 10/16/2020 | 10/07/2020 | ||||||
18-1650-47 | Nailor Industries | Line 1 | Fire/Smoke and Smoke Dampers | 10 | 10 | 10 | 0 | DELIVERED | 10/16/2020 | 10/09/2020 | XPO 855-095986 | 10/26/2020 | 10/20/2020 | illegible | ||||
Line 2 | Motorized Dampers with 120V Actuator | 2 | 2 | 2 | 0 | DELIVERED | ||||||||||||
18-1650-48 | Nailor Industries | Line 1 | 12/12 Plaster Frames | 24 | 24 | 24 | 0 | DELIVERED | 10/15/2020 | 10/07/2020 | FED-EX 165153590101 | 10/12/2020 | 10/13/2020 | DARAGON | ||||
18-1650-49 | Nailor Industries | Line 1 | Grilles, Registers and Diffusers | 2 | 2 | 2 | 0 | DELIVERED | 10/22/2020 | 10/15/2020 | 10/20/2020 | 10/20/2020 | Argon | |||||
18-1650-50 | Vemco, Inc | Line 1 | Lee Temp ASSY | 1 | 1 | 1 | 0 | DELIVERED | 10/26/2020 | 10/19/2020 | XPO 247-032575 | 10/20/2020 | 10/21/2020 | illegible | ||||
Line 2 | 1 | 0 | 0 | 0 | DELIVERED | |||||||||||||
18-1650-51 | Johnson Controls | Line 1 | 1 | 1 | 1 | 0 | DELIVERED | 01/12/2021 | 01/05/2021 | 01/15/2021 | 01/15/2021 | |||||||
18-1650-52 | Nailor Industries | Line 1 | Lost GRDs | 16 | 16 | 16 | 0 | DELIVERED | 03/08/2021 | 02/26/2021 | 02/08/2021 | FED-EX 975315226731 | 02/16/2021 | 02/15/2021 | ERISDOL | |||
18-1650-01 | Johnson Controls | Line 1 | JCI/York Solutions Handling units per schedule and spec. Includes Area for Humidifier Manifold/Dispersion Tubes - ALL PLUMBING AND VENTING BY OTHERS
STARTUP BY OTHERS.
VFDs AND FLEX CONNECTIONS TO EQUIPMENT BY OTHERS | 2 | 0 | 0 | 0 | 10/02/2019 | 746303913 9/25/2019 | 12/31/2019 | ||||||||
Line 2 | JCI Duct Mounted Hot Water Coils | 2 | 0 | 0 | 0 | |||||||||||||
Line 3 | M1.0 AHU Schedule Note 13 Added Inertia Bases – Does not include Concrete | 1 | 0 | 0 | 0 | |||||||||||||
18-1650-02 | Johnson Controls | Line 1 | JCI VAVs with closed Cell Foam Hospital Grade Liner, HW Coil, Hanger Brackets and Access Door
CONTROLS BY OTHERS AND FACTORY MOUNTED | 120 | 0 | 0 | 0 |