Job PO # | Jake - On Broadway | SCS Job # | J-19-1613 |
Sales Engineeer | Gary Wambeke | 406-451-7232 | Project Admin | Liz Pullman | 406-551-7221 |
Updated | 10/17/2022 1:35 am |
PO | Shipping | Delivery | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SCS PO# | MANUFACTURER | TAG | LINE | DESCRIPTION | # ORDERED | # SHIPPED | # DELIVERED | # B/O | STATUS | ORIGINAL ESTIMATED SHIP DATE | REVISED ESTIMATED SHIP DATE | ACTUAL SHIP DATE | TRACKING | NOTES | ESTIMATED DELIVERY DATE | ACTUAL DELIVERY DATE | SIGNED | NOTES |
PO-19-1613-01 | Captive Aire | Line 1 | EF-1, EF-2 and MAU Curbs
Curb for Fan #1 NCA30HPFA - Exhaust Fan (EF-1)
* EF-1 Curb CRB38.5X20E On Fan #1 Flat Curb
- Hinged Base for Curb. Heavy Duty Hinge attached to curb.
Used on Fans with wheels 24-30 inches.
- Vented Base for Curb
Curb for Fan #2 DU12HFA - Exhaust Fan (EF-2)
* EF-2 Curb CRB17.5X12E On Fan #2 Flat Curb
Curb for Fan #3 A2-D.500-20D - Heater (MAU-1)
* MAU-1 Curb CRB21X71X20INS Insulated Flat Curb
- Rail ADJUSTLEG-36 (Set of 2)
| 3 | 3 | 3 | 0 | DELIVERED | 11/26/2019 | 11/27/2019 | OTHER NA | 11/27/2019 | 11/27/2019 | |||||
PO-19-1613-02 | Lewis & Lambert | Line 1 | Lot Low Pressure single wall Aluminum and Galvanized Spiral pipe and fittings with couplers every 10'
APPROX 2150# | 1 | 1 | 1 | 0 | DELIVERED | 02/12/2020 | 02/12/2020 | Motor Freight NA | 02/12/2020 | 02/12/2020 | |||||
PO-19-1613-03 | MJM Associates | Line 1 | Tjernlund Model LB2 Dryer Booster Fan with LT4 Secondary Lint trap | 1 | 1 | 1 | 0 | DELIVERED | 01/24/2020 | 01/24/2020 | UPS NA | 01/24/2020 | 01/24/2020 | |||||
PO-19-1613-04 | Acme Engineering | Line 1 | TAG: EF3 & EF4 - Inline exhaust Fans with Back Draft Damper, Speed Controller shipped loose, Spring vibration Isolation, and disconnect | 2 | 2 | 2 | 0 | DELIVERED | 02/07/2020 | 01/30/2020 | YRC 7559296495 | 02/07/2020 | 02/07/2020 | |||||
PO-19-1613-05 | Crescent Electric | Line 1 | EF3 Motion Sensors | 1 | 1 | 1 | 0 | DELIVERED | 03/04/2020 | 03/04/2020 | Fedex NA | 03/04/2020 | 03/04/2020 | |||||
Line 2 | EF3 & EF4 Motor Starters | 2 | 2 | 2 | 0 | DELIVERED | ||||||||||||
PO-19-1613-06 | Nailor Industries | Line 1 | Manual Volume Dampers with Locking Quadrant and 2" Stand-off | 20 | 20 | 20 | 0 | DELIVERED | 02/21/2020 | 03/06/2020 | XPO 252067712 | 03/16/2020 | 03/16/2020 | Jake Dolezel | ||||
Line 2 | Grilles Registers and Diffusers | 25 | 25 | 25 | 0 | DELIVERED | ||||||||||||
PO-19-1613-07 | Flexmaster | Line 1 | High Efficiency Take-Offs with Damper and 2" Stand-off | 7 | 7 | 7 | 0 | DELIVERED | 01/28/2020 | 01/28/2020 | FedEx 1203742033135 | 02/05/2020 | 02/05/2020 | |||||
Line 2 | Lot Low Pressure Insulated R6.0 Flex Duct | 1 | 1 | 1 | 0 | DELIVERED | ||||||||||||
PO-19-1613-08 | Grainger | Line 1 | EF4 Timeclock - Intermatic | 1 | 1 | 1 | 0 | DELIVERED | 01/25/2020 | 01/25/2020 | NA NA | 01/25/2020 | 01/25/2020 | |||||
PO-19-1613-10 | Captive Aire | Line 1 | Captive Aire Model A1-D.250-G10 Direct Gas Fired Heated Make Up Air Unit with 10" Blower
Supply Fan handles 2400 CFM @ 0.510" wc ESP, Fan runs at 1363 RPM.
Heater supplies 223111 BTUs. 102°F Temperature Rise. [Fuel: Natural Gas]
Supply Motor: 2.000 HP, 1 Phase, 230 V, 60Hz, 8.1 FLA, ODP (Open Drip Proof)
Down Discharge - Air Flow Right -> Left
- Size 2 Celdek Evaporative Cooler for Size # 1 Modular Heater.
36.75" Wide X 32.125" Long X 36.688" High.
For outdoor installation. Min. water pressure for optimal performance is 30 PSI.
Max. water pressure should not exceed 50 PSI. Use with water softener recommeded.
- Sloped Filtered Intake for Size #2 Modular Heater.
26.813" Wide X 53.625" Long X 31.313" High.
Includes 2" MV EZ Kleen Metal Mesh Filters.
- RTC Solutions • 40-90°F Discharge Temp Control
- Gas Manifold for DF1 GM - BTU 0 - 550001 - 7 in. w.c. - 14 in. w.c., No Insurance Requirement (ANSI), BV250-66
- Cooling Interlock Relay. 24VAC Coil. 120V Contacts. Locks out burner circuit when AC is energized.
- Motorized Back Draft Damper 16" X 18" for Size 1 Standard & Modular Heater Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, TFB120S Actuator Included
- Control panel enclosure heater, includes 200w, 120v heater and thermostat (10 degree setting). Requires convenience outlet option (power by others). Recommended for winter design temperature less than 0°F.
- GFCI 15 amp Convenience Outlet For Heater Enclosure. Power supply by others - Includes receptacle and J box.
- Low Fire Start. Allows the burner circuit to energize when the modulation control is in a low fire position.
- Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
- Gas Pressure Gauge, -5 to +15 Inches Wc., 2.5" Diameter, 1/4" Thread Size
- Freeze Protection Drain Control kit for Evaporative Coolers. Includes 3-Way water solenoid valve 8316G064 (shipped loose), Pressure switch installed upstream of 2way solenoid in unit, Brass Tee, 2 NPT half inch nipples, and two stage thermostat T678A1361. Field wiring required by others for 3-way valve. For both Celdek and Standard V-bank type Configurations.
Factory Assisted Startup/Design Verification | 1 | 1 | 1 | 0 | DELIVERED | 04/05/2020 | 04/06/2020 | ABF 155064338 | 04/13/2020 | 04/13/2020 | |||||
Line 2 | TAG: KH-1 - Captive Aire Model 4824ND-2-PSP-F - 12ft 0" Long Exhaust-Only Wall Canopy Hood with 16" Wide Front Perforated Supply Plenum with Built-in 3" Back Standoff
- 430 SS Where Exposed
- Fire Cabinet on the Left Side 12.00" Width x 48" Length x 24.00" Height (Additional charges may apply for cabinet if not sold with fire system)
- FILTER - 20" tall x 16" ( 19.625" by 15.625") wide Stainless Steel Captrate Solo filter with hook, ETL Listed. Particulate capture efficiency: 85% efficient at 9 microns, 76% efficient at 5 microns. Used on hoods shipped AFTER 7/27/17.
- Recessed Allanson Round LED fixture and LED Light, 3500 K warm output.
- EXHAUST RISER - Factory installed 18" Diameter X 4" Height
- SUPPLY RISER - 12"x 20" Supply Riser with Volume Dampers
- 1/2 Pint Grease Cup New Style, Flanged Slotted
- LEFT QUARTER END PANEL 23" Top Width, 0" Bottom Width, 23" High 430 SS
- Electrical Package Installation in Utility Cabinet by Plant.
- RIGHT QUARTER END PANEL 23" Top Width, 0" Bottom Width, 23" High 430 SS
- STRUCTURAL FRONT PANEL
- Parts required to mount prewire sensor in capture volume of hood. Sensor installed directly in line with center of riser and in center of capture volume front to back. Sensor supplied from ECP tied to hood.
TAG: KH-2 - Captive Aire Model 4224VHB-G-REM - 3ft 6" Long Condensate Hood, w/ Full Perimeter Gutter and Removable Baffles
- 430 SS - 100% Application
- EXHAUST RISER - Factory installed 10" Diameter X 4" Height
Fire System #1
ANSUL-3.0/3.0 Ansul 6 gallon Fire System in Utility Cabinet (includes pre-piped hood(s) with detection, tank(s), release mechanism, microswitches and pull station).
Includes piping for hood: 1.
- MGVA2 GAS VALVE - 2" Mechanical Shutoff Valve (Ansul)(28-55610) - Includes Upstream Strainer assembly
Electrical System 1
SC-211110FP 220V 1 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. Includes 1 Duct Thermostat kit.
- Digital Prewire Lighting Relay Kit. Includes hood lighting relay & terminal blocks. Allows for up to 1400W of lighting each.
| 2 | 2 | 2 | 0 | DELIVERED | ||||||||||||
Line 3 | Fan #1 NCA30HPFA - Exhaust Fan (EF-1)
NNCA16FA Belt Drive Centrifugal Upblast Exhaust Fan with 18.75" wheel
Exhaust Fan handles 2775 CFM @ -0.953" wc ESP, Fan runs at 1116 RPM.
Exhaust Motor: 1.000 HP, 1 Phs, 230 V, 60Hz, 4.0 FLA, ODP (Open Drip Proof)
- Grease Cup for kitchen-duty centrifugal exhaust fans,
Box Dimensions 17-1/8 L X 5-1/16 W X 3-3/4 H (18 GA.) (Includes Down Spout)
- Gasketing - Thermeez Woven Ceramic Tape - 1/4" x 1" with adhesive back - Max Temp 1500°F. To be applied between fan base and grease duct. Ships loose with fan. Gasket length supplied = perimeter of fan base.
Fan #2 DU12HFA - Exhaust Fan (EF-2)
DU12HFA High Speed Direct Drive Centrifugal Upblast Exhaust Fan with speed control (speed control included for single phase only), disconnect switch and 10-1/2" wheel.
Exhaust Fan handles 525 CFM @ -0.350" wc ESP, Fan runs at 1601 RPM.
Exhaust Motor: 0.250 HP, 1 Phs, 115 V, 60Hz, 2.9 FLA, TEAO-ECM (Totally Enclosed Air Over Electronically Commutated Motor)
- ECM Wiring Package and Manual or 0-10VDC Control for Exhaust EC motors. RTC Controller (No harness when ordered as a part).
- Gravity Back Draft Damper - with flange, damper is 12" sq. 2" deep, O.D. of flange is 14" sq.
- Bird Screen - 1/2" X 1/2" (3 3/4" X 46") Wire Screen for Direct Drive Upblast/Downblast Fans (850030) DU/DR12, Galv after welded wire cloth.
| 2 | 2 | 2 | 0 | DELIVERED | ||||||||||||
PO-19-1613-11 | Captive Aire | Line 1 | Lot Captive Aire 0 Clearance Grease Duct | 1 | 1 | 1 | 0 | DELIVERED | 05/12/2020 | 05/12/2020 | ABF 155064364 | 05/20/2020 | 05/19/2020 |