Job PO # | 224277 | SCS Job # | J-18-1621 |
Contractor | Tri County Mechanical & Electric - Butte | ||
Sales Engineeer | Gary Wambeke | 406-451-7232 | Project Admin |
Updated | 09/28/2020 1:26 am |
Release | Shipping | Delivery | Freight Claims | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SCS PO# | MANUFACTURER | TAG | DESCRIPTION | # ORDERED | # DELIVERED | # B/O | STATUS | RELEASE | ORDERED | LEAD | NOTES | ESTIMATED | ACTUAL | TRACKING | NOTES | ESTIMATED | ACTUAL | SIGNED | NOTES | ISSUES | CLAIM # | NOTES |
PO-18-1621-01 | Mason Industries | For HVAC Dry Side Scope of work; 1 Lot of Mason Industries Seismic Isolation PER IBC 2012 and Specifications (Seismic Design Category = D, Ip = 1.0)as follows:
1) HVAC Dry Side Seismic Isolation including ductwork 6 square feet area and larger and hanging equipment (including VAV’s):
7 Hanger Locations which include 4 seismic cables per location,
2) Attachment and equipment overturn calculations that will provide engineered anchoring details per local seismic requirements:
0 separate calculations required for equipment attachments
3) As Required Engineered and PE Stamped shop drawings:
4) Vibration Isolation Pads and Spring Hangers for equipment and ductwork:
ZERO Spring Hangers or Pads
5) Quality control documentation and site verification.
****Nuts, bolts, washers, guides, rods, strut, steel angle, embeds and anchor bolts, AND ROD STIFFENERS, AND VIBRATION ISOLATION (other than what has specifically delineated above), AS WELL AS EXISTING PIPE/DUCT/EQUIPMENT by others.
| 1 | 1 | 0 | DELIVERED | 12/04/2019 | 12/04/2019 | 3-4 weeks | 12/20/2019 | 12/16/2019 | 01/01/2020 | 01/01/2020 | |||||||||
PO-18-1621-02 | Flexmaster | Lot Low Pressure R6.0 Insulated Flex Duct | 1 | 1 | 0 | DELIVERED | 12/03/2019 | 12/03/2019 | 5-10 business days | 12/12/2019 | 12/11/2019 | XPO 229-468691 | 12/18/2019 | 12/18/2019 | T. Carpenter | |||||||
High efficiency Take-Offs with Dampers and 2" Stand-off | 10 | 10 | 0 | DELIVERED | 12/03/2019 | 12/03/2019 | 2-3 weeks | 12/12/2019 | 12/11/2019 | XPO 229-468691 | 12/18/2019 | 12/18/2019 | T Carpenter | |||||||||
PO-18-1621-03 | Nailor Industries | Grilles, Registers and Diffusers | 31 | 31 | 0 | DELIVERED | 12/04/2019 | 12/04/2019 | 4-5 weeks | 01/03/2020 | 01/03/2020 | FedEx 4932865571 | 01/09/2020 | 01/09/2020 | PBoerrmann | 2 boxes DAMAGED | Nailor resent entire order - how to handle? | |||||
Single Duct VAV Boxes with HW Coil, Hanger Brackets, Access Dor, Fiber Free Liner. CONTROLS SUPPLIED AND MOUNTED BY OTHERS | 7 | 7 | 0 | DELIVERED | 12/04/2019 | 12/04/2019 | 4-5 weeks | 01/03/2020 | 01/03/2020 | FedEx 4932865571 | 01/09/2020 | 01/09/2020 | PBoerrmann | 2 boxes DAMAGED | Nailor resent entire order - how to handle? | |||||||
Manual Volume Dampers with locking quadrant and 2" Stand-off | 20 | 20 | 0 | DELIVERED | 12/04/2019 | 12/04/2019 | 4-5 weeks | 01/03/2020 | 01/03/2020 | FedEx 4932865571 | 01/09/2020 | 01/09/2020 | PBoerrmann | 2 boxes DAMAGED | Nailor resent entire order - how to handle? | |||||||
PO-18-1621-04 | Lewis & Lambert | Lot medium and low pressure, single wall galvanized spiral pipe and fittings with couplers every 10 feet
Round Only - Approximately 1002#
| 1 | 1 | 0 | DELIVERED | 12/09/2019 | 12/09/2019 | 2-3 weeks | 12/16/2019 | 12/31/2019 | Na NA | 12/10/2019 | 12/10/2019 | ||||||||
PO-18-1621-05 | Nailor Industries | Extruded Aluminum Channel Frame Louvers with Custom Color to be selected by Architect | 2 | 2 | 0 | DELIVERED | 12/10/2019 | 12/10/2019 | 4-5 weeks | 01/17/2020 | 12/23/2019 | XPO 630-598150 | 01/03/2020 | 01/03/2020 | Tyler Leary |